Funktion blocks - room ventilation engineering

By using the controls a complex installation can be programmed through simple mouse clicks.

room ventilation technique

The function blocks for the room ventilation engineering are:

Installation point
  • Release of control and regulation of a room ventilation
Outside air processing
  • Calculation of enthalpy from moisture and temperature
Heat recovery
  • Controlling and regulation of circular network system
  • Controlling and regulation of controllable flaps
  • Controlling and regulation of cross-flow heat exchangers with gate valve
  • Controlling and regulation of a calorific wheel
Gate valves
  • 3.1 Controlling of the flaps
  • 3.2 Hygiene circuit for outside air filters
Air heater
  • PWW - preheater without pump(s), with antifreeze (air and /or water related) 4.2 PWW - preheater with 1 to N pumps, with antifreeze (air and /or water related) 4.3 PWW - sequential heater without pumps
  • PWW - sequential heater with pumps
  • Electric air heater (graded), with safety devices
  • Electric air heater (discrete), without safety devices
  • Electric air heater (continuous), safety devices
  • Electric air heater (continuous), without safety devices
Cooler
  • KW Cooler without pump(s)
  • KW Cooler with pump(s)
  • Controlling of direct evaporator ( 2 point regulation)
  • Controlling of direct evaporator ( continuous regulation)
Ventilators
  • Controlling of unregulated ventilators with 1 to N revolution numbers
  • Controlling of regulated ventilators
  • Controlling of flue gas ventilators
  • Controlling of pressure ventilation installations
  • Controlling of frequency converters with disturbance operation
Air humidifier
  • Air washer with pump, 2 point regulation, feeding and automatic drainage
  • Air washer with pump, continous regulation, feeding and automatic drainage
  • Controlling of direct steam humidifier, 2 point regulation
  • Controlling of direct steam humidifier, continuous regulation
Motor-driven fire protection / smoke extracting valve
  • Fire protection valve
  • Smoke extracting valve
Controller
  • Controller with one output, heating or cooling / humidifying or dehumidifying, analogue outputs
  • Set-point controller with two sequence controllers, heating or cooling / humidifying or dehumidifying, analogue outputs
  • Set-point controller with three sequence controllers heating or cooling / humidifying or dehumidifying, analogue outputs
  • Set-point controller with four sequence controllers heating or cooling / humidifying or dehumidifying, analogue outputs
  • Cascade controller, room / incoming air cascade for temperature or humidity control, analogue outputs
  • Controller with one output, heating or cooling / humidifying or dehumidifying, binary output
  • Set-point shift in dependence of the outside temperature (DIN)
  • h,x dependent control
  • Hysteresis with one analogue input and one binary output
  • Adaptive control
  • Calculation of the dew-point temperature in dependence of the outside temperature


Technical
information


Product news


Reader interface module
XMP-RIM-xxx


Relais Erweiterungskarte

Interface module for the decentralized door control.
  • RS485 2-wire-interface to K32/K32Lite door controller
  • Supports all K32/K32lite reader technologies
  • Also with 2 integrated Wiegand interfaces available
  • 4 supervised inputs
  • 2 to 4 digital relay outputs

Mullion reader
XMP-TMC2230/2240


Türzargenleser

This access-control reader is as well suitable for inside- and also for outside-areas.

| Company | Imprint | Contact | AUTEC Gesellschaft für Automationstechnik mbH